Instrumentation |
|
|
|
|
|
Pressure |
Transmitters and Sensors |
|
|
|
COMPACT PRESSURE
TRANSMITTER CPT |
|
INDUSTRIAL TRANSMITTER NA |
|
|
8220 |
|
 |
8891/3 |
|
Sensor: Thin film on steel |
|
Sensor: Thin film on steel |
|
Measuring range: 0...4 to 0...600 bar |
|
Measuring range: 0...1 to 0...600 bar |
|
|
Signal output: 4...20 mA |
|
|
Signal output: 4...20 mA |
|
|
0.5...4.5 VDC (ratiom.) |
|
0...5 VDC |
|
0...5 VDC |
|
0...10 VDC |
|
|
0...10 VDC |
|
1...6 VDC |
|
NLH (BSL through 0): ± 0.1 % FS typ. |
|
NLH (BSL through 0): ± 0.2 % FS typ. |
|
± 0.2 % FS typ. |
|
Built–in filter EMC, IEC 61000 |
|
|
ECONOMIC PRESSURE
TRANSMITTER |
|
ECONOMIC PRESSURE TRANSMITTER |
|
|
ECOS/ ECOA/ ECOAA 8498 |
|
 |
ECOSR/ ECORV 8498 |
|
Sensor: Thick film on ceramic |
|
(Refrigeration
Transmitter) |
|
Measuring range: 0...1 to 0...250 bar |
|
Sensor: Thick film on ceramic |
|
Signal output: 4...20 mA |
|
Measuring range: 0...1 to 0...40 bar |
|
0...5 VDC |
|
Signal output: 4...20 mA |
|
0...10 VDC |
|
0...5 VDC |
|
|
1...6 VDC |
|
|
0...10 VDC |
|
|
0.5...4.5 VDC (ratiom.) |
|
|
1...6 VDC |
|
|
NLH (BSL through 0): ± 0.3 % FS typ. |
|
|
NLH (BSL through 0): ± 0.3 % FS typ. |
|
|
|
|
|
|
|